Mini UPS

4D(L) AC–DC Mini UPS, 60 W

Reference: 4D(L)

4D(L) UPS reference unit with ribbed metal enclosure and attached cables Enlarge image
4D(L) UPS reference unit with ribbed metal enclosure and attached cables
Manufacturer reference photograph; identifying and generic rating labels edited. Confirm the selected configuration.

4D(L) reference mini UPS with 12 VDC output, a listed 14.8 V lithium-ion battery and capacity up to 3.4 Ah.

Output
12 VDC ±2%
Rated power
60 W
Battery
14.8 V · Up to 3.4 Ah · Lithium-ion

Sample availability, pricing and shipping are confirmed for your configuration.

Specifications

4D(L) AC–DC Mini UPS, 60 W specifications
ParameterStated value
Reference code 4D(L)
Equipment type AC–DC mini UPS
Listed rated power 60 W
AC input voltage 65–265 VAC
AC input frequency 47–63 Hz
DC output voltage 12 VDC ±2%
Battery nominal voltage 14.8 V
Listed battery capacity Up to 3.4 Ah
Battery type Lithium-ion
Dimensions 195 × 142 × 45 mm
Net weight 935 g ±5 g

Values are taken from manufacturer documentation and apply to the listed configuration. Confirm the current model-specific document, conditions and revision before procurement.

Integration notes

Protected load and backup behaviour

Describe the equipment to protect, normal and startup demand in W and VA, selected AC or DC output, and the required backup period. Include the connector, polarity, cable and installation requirements for a configuration review.

Application notes & selection checklist

Compare 4D(L) for a 12 VDC load within the listed 60 W rating. The documented battery is 14.8 V lithium-ion with capacity up to 3.4 Ah; confirm the battery supplied with the selected revision.

Identify normal and startup demand, output connector and polarity, installation conditions and the required behaviour during input loss and recovery. Agree a backup-duration evaluation at the load you intend to protect.

Share the destination market and any output, cable, connector or label requirements for supplier feasibility review. Request current configuration and battery documents through the mini UPS directory.

Output, connection & branding options

Discuss the required output voltage, connector and polarity, cable length, enclosure labelling and packaging. Alarm outputs, dry contacts or other monitoring interfaces require a model-specific feasibility check. Confirm the configuration and test load before sample evaluation.

How we approach validation

Documentation

Electrical, battery & shipping documents

Request the current electrical specification, connector information and battery nameplate. For lithium-battery shipment review, include the applicable UN 38.3 test summary and safety data sheet; packaging, route and carrier acceptance are confirmed before dispatch.

Request UPS documentation