Mini UPS

4D(H) AC–DC Mini UPS, 60 W

Reference: 4D(H)

4D(H) UPS reference unit with ribbed metal enclosure and attached cables Enlarge image
4D(H) UPS reference unit with ribbed metal enclosure and attached cables
Manufacturer reference photograph; identifying and generic rating labels edited. Confirm the selected configuration.

4D(H) reference mini UPS with 12 VDC output, a listed 14.8 V lithium-ion battery and capacity up to 6.8 Ah.

Output
12 VDC ±2%
Rated power
60 W
Battery
14.8 V · Up to 6.8 Ah · Lithium-ion

Sample availability, pricing and shipping are confirmed for your configuration.

Specifications

4D(H) AC–DC Mini UPS, 60 W specifications
ParameterStated value
Reference code 4D(H)
Equipment type AC–DC mini UPS
Listed rated power 60 W
AC input voltage 65–265 VAC
AC input frequency 47–63 Hz
DC output voltage 12 VDC ±2%
Battery nominal voltage 14.8 V
Listed battery capacity Up to 6.8 Ah
Battery type Lithium-ion
Dimensions 195 × 142 × 45 mm
Net weight 1125 g ±5 g

Values are taken from manufacturer documentation and apply to the listed configuration. Confirm the current model-specific document, conditions and revision before procurement.

Integration notes

Protected load and backup behaviour

Describe the equipment to protect, normal and startup demand in W and VA, selected AC or DC output, and the required backup period. Include the connector, polarity, cable and installation requirements for a configuration review.

Application notes & selection checklist

Compare 4D(H) for a 12 VDC load within the listed 60 W rating. The documented battery is 14.8 V lithium-ion with capacity up to 6.8 Ah; confirm the exact battery supplied with the selected revision.

This reference has a higher stated capacity limit than 4D(L). Use your load profile, startup demand and required backup period to define a common evaluation rather than selecting by capacity alone.

Provide the output connector and polarity, mounting limits and destination market. Request the current battery label, configuration and transport documents before a sample shipment, and submit any cable, connector or label requirements through the mini UPS directory.

Output, connection & branding options

Discuss the required output voltage, connector and polarity, cable length, enclosure labelling and packaging. Alarm outputs, dry contacts or other monitoring interfaces require a model-specific feasibility check. Confirm the configuration and test load before sample evaluation.

How we approach validation

Documentation

Electrical, battery & shipping documents

Request the current electrical specification, connector information and battery nameplate. For lithium-battery shipment review, include the applicable UN 38.3 test summary and safety data sheet; packaging, route and carrier acceptance are confirmed before dispatch.

Request UPS documentation