Mini UPS

4B(L) AC–AC Mini UPS, 150 W Maximum

Reference: 4B(L)

4B(L) UPS reference unit with ribbed metal enclosure and attached cables Enlarge image
4B(L) UPS reference unit with ribbed metal enclosure and attached cables
Manufacturer reference photograph; identifying and generic rating labels edited. Confirm the selected configuration.

4B(L) reference AC–AC mini UPS with listed maximum power of 150 W and a 14.8 V, 3.4 Ah lithium-ion battery.

Output
AC · confirm voltage option
Maximum power
150 W
Battery
14.8 V · 3.4 Ah · Lithium-ion

Sample availability, pricing and shipping are confirmed for your configuration.

Specifications

4B(L) AC–AC Mini UPS, 150 W Maximum specifications
ParameterStated value
Reference code 4B(L)
Equipment type AC–AC mini UPS
Listed maximum power 150 W
AC input voltage 65–265 VAC
AC input frequency 47–65 Hz
Battery-mode output frequency 50 / 60 Hz ±1 Hz
Battery nominal voltage 14.8 V
Nominal battery capacity 3.4 Ah
Battery type Lithium-ion
Dimensions 195 × 142 × 45 mm
Product weight 895 g ±5 g

Values are taken from manufacturer documentation and apply to the listed configuration. Confirm the current model-specific document, conditions and revision before procurement.

Integration notes

Protected load and backup behaviour

Describe the equipment to protect, normal and startup demand in W and VA, selected AC or DC output, and the required backup period. Include the connector, polarity, cable and installation requirements for a configuration review.

Application notes & selection checklist

Review 4B(L) as an AC-output reference with a listed maximum power of 150 W and a 14.8 V, 3.4 Ah lithium-ion battery. Ask for the continuous-load limit and selected output-voltage option for the proposed configuration.

Describe load power and VA demand, startup behaviour, output voltage and frequency, and the permitted interruption. Request a runtime evaluation at the stated load and confirm the intended indoor installation conditions.

Include the destination market and any connector, cable or label requirements in the supplier feasibility brief. Request current battery and electrical documents through the mini UPS directory.

Output, connection & branding options

Discuss the required output voltage, connector and polarity, cable length, enclosure labelling and packaging. Alarm outputs, dry contacts or other monitoring interfaces require a model-specific feasibility check. Confirm the configuration and test load before sample evaluation.

How we approach validation

Documentation

Electrical, battery & shipping documents

Request the current electrical specification, connector information and battery nameplate. For lithium-battery shipment review, include the applicable UN 38.3 test summary and safety data sheet; packaging, route and carrier acceptance are confirmed before dispatch.

Request UPS documentation